The primary purpose of a LACT system is to measure and transfer process fluid from one location to another.  Valin produces LACT systems for 3 basic applications: a pipeline LACT, a truck loading LACT, and a truck unloading LACT.  The table below gives examples of each.  Valin also manufactures for applications other than those identified below.

Application Supply (Inlet) Delivery (Outlet)
Pipeline LACT Storage Tank Pipeline
Truck Loading LACT Storage Tank Truck or Rail Car
Truck Unloading LACT Truck Storage Tank
Combination Pipeline & Truck Loading LACT Storage Tank Pipeline, Truck or Rail Car

Environment

  • Warm
    • Year round temperatures between 32°F and 100°F
    • Ecology Rail (Enclose skid frame), Floor plate, Lifting lugs
    • Haz Class I Div II
      • Optional - Haz Class I Div I
  • Cold
    • Year round temperatures between -40°F and 105°F
    • Enclosure
    • HVAC unit
    • Remote Enclosure
    • Heated actuators
    • Haz Class I Div II
      • Optional - Haz Class I Div I

Process Fluid

  • Light – API > 30°
  • Medium – 20° < API < 30°
  • Heavy – 10° < API < 20°
  • Extra Heavy – API < 10°

Sizing

Flow Rate - Size

  • 2”, 3”, 4”
  • Table per class and oil weight
  • Pressure drop graph per platform

Model Characteristics

150lb - Light

 

 

Design Parameters

2"

3"

4"

Max Flow Rate

100 GPM (150 BPH)

245 GPM (350 BPH)

420 GPM (600 BPH)

Pressure

275 psi

275 psi

275 psi

Temperature

100 deg F

100 deg F

100 deg F

Fluid Gravity

0.7 - 0.9 SG

0.7 - 0.9 SG

0.7 - 0.9 SG

Viscosity**

0-10 cP

0-10 cP

0-10 cP

Pressure Drop *

10-30 psi

10-30 psi

10-30 psi

Flange class

ANSI Cls. 150

ANSI Cls. 150

ANSI Cls. 150

Flow Accuracy

0.05% (rate)

0.05% (rate)

0.05% (rate)

Repeatability

per API

per API

per API

Model Descriptions and Options

  • Standard - $
    • Manual
  • Plus - $$
    • Semi - Automated
  • Elite - $$$
    • Fully automated
    • Feedback
Component Description
Standard Plus Elite

Inlet Valve

Manual Actuated Actuated with position feedback

Strainer

None Standard w/dp gauge High Capacity w/DP Gauge, transmitter, alarm

Diff Pressure 

None Pressure Gauge Pressure Transmitter

Charge Pump

     

Air Eliminator

None Air eliminator valve AE on Strainer; Option: Vessel

Cut Monitor

 Improve accuracy, reliability, tranmitting options

Divert Valve

None Actuated; No BPV Actuated w/feedback; BPV Included

Sampler

API bevel probe Isokinetic Isokinetic with failure alarm

Sampler System

Quick release lid T-bolt head ASME code vessel

Sampler System Size

10 gal 15 gal 20 gal

Liquid Flow Meter

Single PD meter Dual PD meter/Coriolis Multi variable Coriolis

Pressure Measurement

Gauge Transmitter Transmitter w/ display

Temperature Measurement

Gauge Transmitter Transmitter w/ display

Prover Manifold & DBB

Ball Valve Plug Block & Bleed w/indicator Plug Block & Bleed w/switches

BPV

Self contained Self contained V-ball control valve w/ Actuator & feedback

Skid Outlet

Manual Actuated Actuated with position feedback

Control System

Junction Box PLC with readout PLC w/ HMI and SCADA

Safety Components / Options

  • Grounding device
  • Beacon
  • Alarm
  • “Fail Safe” automation

Valin can customize our LACT systems to meet any needs.