Share on

Pipeline-LACTS

Pipeline LACTs

Pipeline LACT are generally located in the field on a lease and hooked up to a delivery pipeline.  Traditionally they are supplied by a supply or storage tank that has high and low level switches.  When the high level switch is activated the pump on the LACT skid is turned on.  Once an acceptable BS&W value is achieved the flow meter will begin measuring the amount of fluid that passes through.  As the oil flows a sample of a given volume is taken and stored in the sample container.  The LACT controller will record volume, temperature and oil quality measurements.  Once the low level switch is activated the pump is turned off.  This type of system can be fully automated.

  • Discharge to a pipeline
  • Pressure switches to protect the pump

Back to Selection Guide

Technical Support

side icon1
side icon2
side icon3
side icon4

Customer Testimonial

“Valin Measurement Group drastically increases production measurement and reduces pressure drop through their LACT units.”

Eagle Ford Shale Asset Manager